Renzan™
Peripheral Stent System
A self-expanding nitinol stent on a rapid exchange delivery catheter, designed for flexibility, conformability and accurate placement1
true
Request Information
Specifications and order codes
false
Renzan™ Peripheral Stent System - Self-Expanding Peripheral Nitinol Stent
2
neutrals-100
false
Nitinol braided wire design enhancing flexibility and conformability1
Three flare markers providing clear visibility1
Predictive markers on the delivery system enabling accurate stent placement1
More Control, More Comfort, No Compromises with the Renzan™ Peripheral Stent System
2
neutrals-100
The Renzan™ Peripheral Stent System consists of a self-expanding nitinol stent which is pre-mounted on the distal portion of a rapid exchange (RX) delivery catheter.1 Renzan™ device is a peripheral stent engineered for dynamic vessel environments and indicated for the treatment of peripheral vascular disease.
grid-texts-60
image-media-type
media-left
How to Prepare the Renzan™ Peripheral Stent System
2
neutrals-100
brightcove
6343175799112
This video demonstrates the preparation of the delivery system, insertion techniques, stent deployment with resheathing and repositioning, as well as safe removal of the device.
Renzan™: A Peripheral Stent Designed for Clear Visualization and Accurate Placement<sup>1</sup>
2
neutrals-100
Stent Design of the Renzan™ Peripheral Stent System
- Balanced outward and radial resistive forces intended to maintain vessel patency and minimise vessel trauma¹
- Nitinol braided wire design enhances flexibility and conformability in dynamic vessel movement1
- Six atraumatic end caps with atraumatic geometry are designed to minimize vessel wall interaction during and after deployment2
grid-texts-60
image-media-type
media-left
Visibility
- Three flare markers provide clear visibility under fluoroscopy¹
- Dual-layer markers at the distal stent end highlight the start of the micromesh section¹
grid-texts-60
image-media-type
media-left
A delivery system ensuring accurate stent placement1
- Predictive markers on the delivery system enable accurate stent placement¹
- A partially deployed stent can only be recaptured and repositioned up to 3 times when a minimum of 20mm of stent length remains inside the catheter.
grid-texts-60
image-media-type
media-left
General Specifications of the Renzan™ Peripheral Stent System
2
neutrals-100
Learn more about the general specification of the Renzan™ Peripheral Stent System.
neutrals-100
Available Lengths and Diameters of the Renzan™ Peripheral Stent System
2
neutrals-100
Learn about the extensive size options available for the Renzan™ Peripheral Stent System.
neutrals-100
* 122 cm working length applies to the following stents: 7mm x 150mm, 8mm x 120mm, 8mm x 150mm
Disclaimer:
Intended Purpose: The Renzan™ Peripheral Stent System is indicated for use in patients with Peripheral Vascular Disease. Refer to instructions for use, contraindications and warnings for additional information. Renzan device is manufactured by MicroVention Europe and distributed by Terumo Europe N.V. All brand names are trademarks or registered trademarks owned by TERUMO CORPORATION, its affiliates, or unrelated third parties. ©2026 Terumo Corporation. ⲤⲈ 0297
MM2269(i) EMEA 04/26
References
text
Data on file.
text
GLP Chronic Evaluation of Dual Layer Micromesh Metal Stent Graft in the Peripheral Arteries of Swine, RD13-013 and RD17-017
Related products
2
neutrals-100
default-carousel
default-carousel
Destination™
Guiding Sheath
default-carousel
NaviCross™
Support Catheter
default-carousel
Radifocus™ Glidewire Advantage™ Family
Guide Wire
default-carousel
FemoSeal™
Vascular Closure System
default-carousel
Crosstella™ OTW
PTA Balloon Dilatation Catheter
Didn't find your product?
Consult our products in our Product Index
neutrals-100
Product Index
Product Index
link