Outlook™​
Angiographic Catheter​
The Outlook™ Angiographic Catheter is a diagnostic catheter designed to deliver radiopaque media and therapeutic agents to selected vascular target sites. ​
true
/content/terumo-europe-ia/en/interventional-systems/contact
Request Information
#ABC
Specifications and order codes
false
Product Highlights
2
neutrals-100
false
High pressure limits
Smooth catheter engagement
Single-catheter concept
Outlook™ Angiographic Catheter ​| A Diagnostic Catheter with Power Through a Small Diameter
2
neutrals-100

Whether delivering radiopaque media, therapeutic agents, or advancing a guidewire, the Outlook™ Angiography Catheter is a diagnostic catheter intended for use in angiographic procedures.​

With a 4 Fr (1.40 mm) outer diameter, the Outlook™ Angiographic Catheter features a large inner lumen for high-flow contrast media injection1.​

It is designed to show good torque control1.​

The pigtail catheter includes a convenient inserter that straightens the tip for easier sheath entry and can be peeled away after placement. ​

Fixed strain relief helps prevent kinking at the proximal end2.​

grid-texts-60
image-media-type
media-left
A Diagnostic Catheter for High Flow Rates, Flexibility and Efficiency<sup>1</sup>
2
neutrals-100
High pressure limits
The thin-walled design allows flow rates up to 23 ml/sec(saline) and withstands a maximum pressure of 1,200 psi(8,274 kPa)3.
grid-texts-60
image-media-type
media-left
Smooth catheter engagement
Double-braiding with variable pitch designed to offer proximal support and increased flexibility at the distal end of the catheter, to promote a smooth catheter engagement1.
grid-texts-60
image-media-type
media-left
Single-catheter concept​
With Tiger and BLK curves, this catheter enables angiography of both right and left coronary arteries via radial or brachial access. This single-catheter approach reduces procedure and fluoroscopy times, improving both efficiency and cost-effectiveness4.
grid-texts-60
image-media-type
media-left
Pressure Limit, Diameter and Guidewire Compatibility of Outlook™Angiographic Catheter
2
neutrals-100
Available Lengths and Shape Variations for Outlook™ Angiographic Catheter
2
neutrals-100
/content/terumo-europe-ia/fragments/tis/spreadsheets/product-specifications/outlook/itemspecs-outlook-angiographiccatheter
Pack size: 5 pieces per box
amplazrightar2
Amplatz Right AR-2
anglepigtail145
Angled Pigtail
anglepigtail155
Angled Pigtail
bypassbpjl
Bypass
internalmammanryjp
Internal Mammary
internalmammanrytip
Internal Mammary
rightjr4
​Judkins Right
rightjr3.5
Judkins Right
vertibral
​Vertebral (Soft Tip)
minicath
Mini Cath-Standard
minicath60
​Mini Cath-Standard 60°
cobra
Cobra Middle
leftjl4
Judkins Left
leftjl3.5
Judkins Left
leftjl5
Judkins Left
radial
Radial
simmons2
Simmons/Sidewinder 2
amplazrightar
Amplatz Right AR-JP
amplazleftal2
amplazleftal3
Amplatz Left AL-3
amplazrightar1
radialtiger5
Radial Tiger II-5.0
simmons1
Simmons/Sidewinder 1
radialtiger4
Radial Tiger II-4.0
amplazleftal1
Amplatz Left AL-1
radial3.5
Radial Tiger II-3.5
radial4
Radial Tiger I -4.0
straightpigtail
Straight Pigtail
multipurposegamal
Multipurpose El Gamal 2
jcurvemiddle
J Curve Middle
rightjr5
Judkins Right
multipurpose2.5
Multipurpose MP-2.5
multipurpose4
Multipurpose MP-4.0
radial3.5
radial4.0
radialima
bypassjr
straightpigtailsm
Related Solutions
2
neutrals-100
variation-1
cards-2
light-grey-bg
variation-1-card
nothing

Explore our Radial Solutions

For 30 years, we have brought radial access to the forefront of clinical practice. Discover how our solutions can contribute to the success of your radial practice.
Learn more
/content/terumo-europe-ia/en/interventional-systems/solutions/radial-solutions
button
variation-1-card
nothing

Explore our Femoral Solutions

Maintaining femoral proficiency is critical as not all interventions can be done radially. Discover how our solutions can support your femoral practice.
Learn more
/content/terumo-europe-ia/en/interventional-systems/solutions/femoral-solutions
button

References

text
Data on file at Terumo Corporation - DC-0060172
text
Data on file. Ref TAC-001.
text
Seong-Man Kim et al_Novel Diagnostic Catheter specifically designed for bothcoronary arteries via the right transradial approach_Int. J. Cardiovasc. Imaging _2005;10.007/s10554-005-9029-8.
text
Seong-Man Kim et al_Novel Diagnostic Catheter specifically designed for bothcoronary arteries via the right transradial approach_Int. J. Cardiovasc. Imaging _2005;10.007/s10554-005-9029-8.

Disclaimer​

Not all products are available for sale in all countries. This information is provided only in respect to markets where these products are approved or cleared. Please contact your Terumo local sales representative for more information. Refer to Instructions for Use for contraindications, warnings, precautions and additional information. All brand names are trademarks or registered trademarks owned by TERUMO CORPORATION, its affiliates, or unrelated third parties.​

neutrals-100
Related products
2
neutrals-100

Didn't find your product?

Consult our products in our Product Index

neutrals-100