Chemoembolization with BioPearl™ microspheres
2
neutrals-100
false
Continuous degradation process1​
Embolic effect2
Sustained chemotherapeutic drug release3
BioPearl™ microspheres - Resorbable Drug-Eluting Microspheres​
2
neutrals-100
BioPearl™ microspheres are resorbable drug-eluting microspheres that represent an advancement in transarterial chemoembolization (TACE). Indicated for embolization of blood vessels supplying hypervascular primary tumors or metastases in the liver.​
grid-texts-60
image-media-type
media-left

BioPearl™ microspheres undergo resorption within the vasculature over time. As they degrade, physiological blood flow is progressively restored. This could offer the possibility for repeated chemoembolizations or other intra-arterial procedures.​

BioPearl™ microspheres are compatible with Doxorubicin, Epirubicin, and Idarubicin, which can be loaded prior to embolization and then, as a secondary action, elute a local, controlled, and sustained dose to the tumor after embolization.1  ​

Note: When used for drug loading, drug loading should be done under a physician’s direction, choice and responsibility, based on type and dose of drug most beneficial to the patient.1

neutrals-100
BioPearl™ microspheres Technical guidance​
2
neutrals-100
Protecting Liver Function to Enable Future HCC Treatment Options
2
neutrals-100
Liver function is a critical determinant of survival in patients with HCC undergoing TACE4. Despite the use of well-established chemoembolization techniques, hepatic injury and insufficiency remain the most frequently observed adverse effects5. Maintaining liver function during and after HCC TACE procedures is essential to preserve the possibility of potential follow-up interventions, including surgery, systemic therapy, or other intra-arterial locoregional treatments6.
grid-texts-60
image-media-type
media-left

As resorbable drug-eluting microspheres, BioPearl™ microspheres have been designed to allow progressive blood flow restoration2, thereby could be retaining the potential for subsequent interventions.​

BioPearl™ microspheres enable:​

  • Continuous degradation driven by an aqueous environment1.​
  • Restoration of blood flow1: Designed to allow progressive blood flow restoration.​

Therapeutic efficacy has been demonstrated in pre-clinical studies1 and is supported by early clinical experience.7

grid-texts-60
image-media-type
media-left
BioPearl™ microspheres combine the confidence of drug-eluting microsphere technology with sustained chemotherapeutic release<sup>3</sup> and an embolic effect<sup>2​</sup>
2
neutrals-100

Chemoembolization with Sustained Drug Release4

When loaded with chemotherapeutic agents such as Doxorubicin, BioPearl™ microspheres demonstrate a similar elution profile as LifePearl™ microspheres4. ​

BioPearl™ microspheres Case Studies: Restoration of blood flow over time​
2
neutrals-100

Restoration of blood flow over time:

  • Patient: 57-year-old man, HCV-positive, BCLC B ​
  • Tumour: Three nodules in liver segments VI, VIII, IV
  • Treatment: BioPearl™ microspheres loaded with Doxorubicin
Embolic effect
2
neutrals-100

Embolic effect:

  • Patient: 72-year-old male with NASH, BCLC A stage HCC ​
  • Tumour: Single 4 cm lesion ​
  • Treatment: BioPearl™ microspheres loaded with Doxorubicin
General Specifications for BioPearl™ Resorbable Drug-Eluting Microspheres
2
neutrals-100
Available Size Range for BioPearl™ Resorbable Drug-Eluting Microspheres​
2
neutrals-100

Are you ready to take TACE to the next level ?

TACE is standard of care in the BCLC guidelines for HCC, and we recognise that there is still scope for improvement, for example complete response rates, duration of response, leading to the need for retreatment.
Learn more
/content/terumo-europe-ia/en/interventional-systems/solutions/advanced-tace
button tis-primary
grid-texts-60
text-vertical-center
image-media-type
aspect-ratio-4-3
media-left

References

text
BioPearl™ Instructions for use 2020​
text
Data on file: TR18-174B – BioPearl™ Liver studies​
text
Data on file: JRD20-0122
text
Imam Waked et al Transarterial chemo-embolisation of hepatocellular carcinoma: impact of liver function and vascular invasion. British Journal of Cancer (2017) 116, 448–454 | doi: 10.1038/bjc.2016.423
text
Mohamed A S Kohla et al Predictors of hepatic decompensation after TACE for hepatocellular carcinoma BMJ Open Gastro 2015;2: e000032. doi:10.1136/ bmjgast-2015-000032
text
A Vogel et al Hepatocellular carcinoma: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up Annals of Oncology 29 (Supplement 4): iv238–iv255, 2018 doi:10.1093/annonc/mdy308
text
R. Iezzi et al: Transarterial Chemoembolization with BioPearl™ Microspheres for the treatment of HCC; 2025 Feb 23;18(3):307. doi: 10.3390/ph18030307

Intended Purpose / Indications:​

BioPearl™ microspheres are indicated for embolization of blood vessels supplying hypervascular primary tumors or metastases in the liver. Note: BioPearl™ microspheres can be loaded with chemotherapeutic drugs. When used for drug loading, drug loading should be done under a physician’s direction, choice and responsibility, based on type and dose of drug most beneficial to the patient. BioPearl™ Microspheres are compatible with doxorubicin, epirubicin, and idarubicin, which can be loaded prior to embolization and then, as a secondary action, elute a local, controlled, and sustained dose to the tumor after embolization. ​

Refer to Instructions for Use for contraindications, warnings, precautions and additional information. ​

BioPearl™ microspheres are not available for sale in all countries. This information is provided only in respect to markets where this product is approved or cleared. Please contact your Terumo local sales representative for more information. ​

BioPearl™ microspheres are manufactured by MicroVention and exclusively distributed by Terumo Europe NV in EMEA region. ​

Manufacturer: MicroVention Europe SARL - 30 bis, rue du Vieil Abreuvoir - 78100 Saint-Germain-en-Laye - France - Tel: +33(0)1 39 21 77 46.​

Distributor: Terumo Europe N.V. - Interleuvenlaan 40 - 3001 Leuven - Belgium -Tel: +32 16 38 12 11.​

All brand names are trademarks or registered trademarks owned by TERUMO CORPORATION, its affiliates, or unrelated third parties. ©2026 Terumo Corporation

ⲤⲈ 0297