​​The Surshield protector of the Surshield™ Versatus I.V. Catheter with Protector allows to completely close the needle, in order to prevent accidental needle stick injuries when disposing of the intravenous cannula. Using a safety catheter does not require any change in the insertion technique.

Sharps protection for healthcare workers provides an important tool in the healthcare setting. The use of safety devices has been proven beneficial in the prevention of sharps injuries in the hospital and healthcare sector.1,2

22245745.jpg

Characteristics

​See and feel the difference

The improved white safety block shows 65% less detachment resistance (compared to previous version3) when removing it from the catheter hub. 

A lower detachment force means less resistance in the separation between the safety mechanism and the catheter hub, so that this final step is less difficult and more comfortable for the patient.

Achieve extra safety without changing your habits


The improved safety device:
  • activates passively while extracting the needle - Easy to use
  • fully covers the tip of the needle ensuring effective protection - Safe
  • has no metal parts potentially scratching and contaminating - Convenient
  • ensures that blood is contained within the device avoiding possible cross contamination - Hygienic

Patented safety mechanism with double protection

  • reduces the risk of accidental needle sticks
  • avoids any blood contamination

Preparation

Video instructions

 

​Always consult the product label for a complete overview of warnings, cautions and/or precautions prior to actual use.

General specifications

​Special tip design for smooth and less painful vein-puncture


  • Conical tip shape facilitates insertion.
  • Optimal gap distance between catheter and bevel.
  • Triple sharpened and back cut bevel needle minimizes pain to the patient.

Thin walled design allows down-sizing


A larger internal lumen gives better flow rates than regular walled catheters at same gauge size. Down-sizing means less mechanical irritation and insertion trauma for the patient.

Item specifications

Choose from a full range portfolio for all clinical needs - Including sizes for neonates and infants


Straight:

Reference ​
Colour code

External Diameter

Internal
Diameter
(mm)
Catheter
Length
(mm) ​
Flow
Rate
(ml/min)
G mm​
SR+DS2619SD
Violet
26​0.640.45​19​19​
SR+DS2419SD
Yellow240.740.551929
SR+DS2225SD
Blue220.900.652542
SR+DS2032SD
Pink201.000.753259
SR+DS1832SD
Green181.300.9532103
SR+DS1845SD
Green181.300.954596
SR+DS1745SD
White171.501.1545155
SR+DS1645SD
Grey161.751.3545225
SR+DS1445SD
Orange142.001.5545290


Winged:

Reference Colour code

External Diameter​

Internal
Diameter
(mm)
Catheter
Length
(mm) ​
Flow
Rate
(ml/min)
G mm​
SR+DS2619WD
Violet
26​0.640.45​​19​19
SR+DS2419WD
Yellow240.740.551929
SR+DS2225WD
Blue220.900.652542
SR+DS2032WD
Pink201.000.753259
SR+DS1832WD
Green181.300.9532103
SR+DS1845WD
Green181.300.954596
SR+DS1745WD
White171.501.1545155
SR+DS1645WD
Grey161.751.3545225
SR+DS1445WD
Orange142.001.5545290


Winged and Ported:

Refere​nce ​Colour code ​

External Diameter​

Internal
Diameter
(mm) ​
Catheter
Length
(mm) ​
Flow
Rate
(ml/min)
G ​mm
SR+DS2619PD
Violet
26​0.640.45​​19​19
SR+DS2419PD
Yellow240.740.551929
SR+DS2225PD
Blue220.900.652542
SR+DS2032PD
Pink201.000.753259
SR+DS1832PD
Green181.300.9532103
SR+DS1845PD
Green181.300.954596
SR+DS1745PD
White171.501.1545155
SR+DS1645PD
Grey161.751.3545225
SR+DS1445PD
Orange142.001.5545290


Unit box: 50 pieces
Shipping carton: 200 pieces
Shelf life: 5 years
Sterilisation: EO

Downloads

References

1European Directive 2010/32/EU implementing the Framework Agreement on prevention from sharp injuries in the hospital and healthcare sector concluded by HOSPEEM and EPSU. 

2Hendrickx J., KUL Belgium, Survey on sharps injuries in nursing staff and medical laboratory technologists: results report, only available in Dutch & French.

3Internal data.

​Always consult the product label for a complete overview of warnings, cautions and/or precautions prior to actual use.

Do you need more info about this product?

Our sales representatives are here for you.

Contact us
Send us a message
 
I have read and accept Terumo Privacy And Cookies Policy and the Terms Of Use*
I wish to receive information and marketing updates from Terumo.
* mandatory fields

Thank you for contacting us!

We typically respond within 2 business days and will come back to you as soon as possible.

Didn't find your product?

Consult our products in our Product Index

Are you a healthcare professional?

This webpage can include promotional content regarding one or several products of Terumo Europe, or some procedures concerning the use or implantation of such products. This webpage is exclusively intended for healthcare professionals and is in no event directed to the general public


For Pharmaceutical Professionals interested in our B2B products portfolio, please visit Terumo Pharmaceutical Solutions.