Skip Ribbon Commands
Skip to main content

Hemocor HPH™

Hemoconcentrator

Description

To control hemodilution during cardiopulmonary bypass surgery.

Characteristics

  • Low prime volume
  • No-rinse filter
  • Gentle ultrafiltration rates
  • Low pressure drop

General specifications

HPH Hemoconcentrators
Membrane materialPolysulfone
Molecular weight cut-off65,000 Daltons
Maximum transmembrane pressure*500 mmHg (66.5 kPa)
Fiber internal diameter

HPH MINI: 620 microns

All other: 200 microns

*Refer to TMP formula

HPH
Junior
HPH
Mini
HPH 400HPH 700HPH 1000
Membrane surface area0.09 m²0.07 m²0.30 m²0.71 m²1.06 m²
Prime volume8 mL14 mL34 mL56 mL84 mL
Pressure drop88 mmHg1 30 mmHg2
61 mmHg3
142 mmHg4
85 mmHg3
Overall unit length5.9" (15.0 cm)5.9" (15.0 cm) 5.4" (13.8 cm)10.0" (25.3 cm)10.0" (25.3 cm)
Internal unit diameter1.0" (2.5 cm)1.0" (2.5 cm) 1.2" (3.0 cm)1.3" (3.2 cm)1.3" (3.2 cm)
​Effective fiber length
​9.52 cm
​9.52 cm
​9.4 cm
​20.9 cm
​20.9 cm

1In vitro test results with bovine blood, end-to-end pressure drop, inlet conditions:Hct = 32 + 2%, total protein = 6.0 g/dl, temp = 33OC, Qb = 100 mI/min, TMP = 100 mmHg.

2In vitro test results with bovine blood, end-to-end pressure drop, inlet conditions:Hct = 25 + 2%, total protein = 6 g/dl, temp = 37OC, Qb = 200 mI/min, TMP = 100 mmHg.

3In vitro test results with bovine blood, end-to-end pressure drop, inlet conditions:Hct = 25 + 2%, total protein = 5 g/dl, temp = 37OC, Qb = 200 mI/min, TMP = 200 mmHg.

4In vitro test results with bovine blood, end-to-end pressure drop for HPH 700, inlet conditions:Hct = 25 2%, total protein = 6.0 g/dl, temp = 37OC, Qb = 200 mI/min, TMP = 200 mmHg.

Tubing connections ​ ​ ​ ​ ​
BloodMale luerMale luer1/4" (6.35 mm)1/4" (6.35 mm)1/4" (6.35 mm)
FiltrateFemale luerFemale luer1/4" (6.35 mm)1/4" (6.35 mm)1/4" (6.35 mm)

Item specifications

​Hemocor® HPH Hemoconcentrators

Description​Catalog #Units/Case
Minitech Hemocor HPH Hemoconcentrators MINI.png

​No-rinse 0.07 m² (accessory connector package supplied)

​HPHMINI

4​
Minitech Hemocor HPH Hemoconcentrators JUNIOR.png

​No-rinse 0.09 m² (accessory connector package supplied)

HPHJUNIOR4​

 

Holder

​Description​Catalog#​Units/Case
​Holder for Hemocor® HPH HemoconcentratorHCH1​1​

For adult use, visit following product site: here

Do you need more info about this product?

Our sales representatives are here for you.

Contact us
Send us a message
I have read and accept Terumo Privacy And Cookies Policy and the Terms Of Use*
I wish to receive information and marketing updates from Terumo.
* mandatory fields

Thank you for contacting us!

We typically respond within 2 business days and will come back to you as soon as possible.

Didn't find your product?

Consult our products in our Product Index

Are you a healthcare professional?

This webpage can include promotional content regarding one or several products of Terumo Europe, or some procedures concerning the use or implantation of such products. This webpage is exclusively intended for healthcare professionals and is in no event directed to the general public


For Pharmaceutical Professionals interested in our B2B products portfolio, please visit Terumo Pharmaceutical Solutions.