Oxygenator

Balanced Performance

  • Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance.
  • Hollow fibers manufactured exclusively by Terumo using a patented technology with total quality management from raw materials to finished product.
  • Woven fiber bundle ensures consistent and high-performance gas exchange.
  • Choice of blood outlet port configurations for easy access and increased circuit flexibility.
  • Top-to-bottom blood flow path and air purge line provide excellent air removal capability.
  • No DEHP used in PVC tubing.

 


Hardshell Reservoir

Full Featured

  • Elongated shape provides a stable blood flow path and enhanced visibility at all levels from all angles.
  • Rotating venous inlet improves set-up flexibility.
  • No DEHP used in PVC tubing.
  • Connecting mount increases flexibility in circuit set-up and oxygenator rotation.
  • Funnel-shaped cardiotomy filter improves breakthrough and residual volumes.
  • Positive pressure relief value for additional safety.

Characteristics

  • Terumo’s exclusive hollow fiber
  • High flow with very low priming volume
  • Superior O2 transfer performance
  • Outstandingly low pressure drop

General specifications

Oxygenator

OxygenatorRX15 R30 reservoirRX15 R40 reservoirRX25
 Housing materialPolycarbonate ​ ​
 Fiber materialMicroporous polypropylene ​ ​
Heat exchanger materialStainless steel ​ ​
Fibers: Approx. surface area1.5 m²
1.5 m²
2.5 m²
Heat exchanger: Approx. surface area0.14 m²0.14 m²0.2 m²
Blood flow range0.5 - 4.0 L/min0.5 - 5.0 L/min0.5 - 7.0 L/min
Priming Volume (static)135 mL
135 mL250 mL
Blood inlet port (from pump)3/8" (9.5 mm) ​ ​
Blood outlet port3/8" (9.5 mm) ​ ​
Cardioplegia port1/4" (6.4 mm) ​ ​
Gas inlet port1/4" (6.4 mm) ​ ​
Gas outlet port1/4" (6.4 mm) ​ ​
Water ports1/2" (12.7 mm) Hansen quick connect fittings ​ ​
Maximum pressure Blood inlet133 kPa (1.000 mmHg) ​ ​
Maximum pressure Water inlet196 kPa (2 kgf/cm²)(28.5 psi) ​ ​

 

Hardshell reservoir

Hardshell ReservoirRX15 R30 reservoirRX15 R40 reservoirRX25
Housing material Polycarbonate ​ ​
Venous filter materials Polyester screen type ​ ​
Cardiotomy filter materialPolyester depth type ​ ​
Defoamer materialPolyurethane foam ​ ​
Blood flow range: Venous 0.5 – 4.0 L/min
0.5 - 5.0 L/min
0.5 - 7.0 L/min
Blood flow range: Cardiotomy inlet4.0 L/min5.0 L/min5.0 L/min
Blood flow range: Combined flow4.0 L/min5.0 L/min
7.0 L/min
Blood storage capacity3.000 mL4.000 mL4.000 mL
Minimum operating volume70 mL200 mL200 mL
Venous blood inlet port (rotatable)
 > when 1/4" adaptor is attached
3/8" (9.5 mm);
1/4" (6.4 mm)
1/2" (12.7 mm) ​
Blood outlet port (to pump)
 > when 1/4" adaptor is attached
3/8" (9.5 mm);
1/4" (6.4 mm)
3/8" (9.5 mm) ​
Suction ports (rotatable)Six: 1/4" (6.4 mm) ​ ​
Vertical port (to CR filter)3/8" (9.5 mm)     ​ ​
Quick prime port1/4" (6.4 mm)     ​ ​
Vent port1/4" (6.4 mm)     ​ ​
Auxiliary port1/4" – 3/8" (6.4 mm – 9.5 mm)     ​ ​
Luer portsThree filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer locks on venous inlet ​ ​
Maximum sustainable negative pressure in reservoir-20.0 kPa (-150 mmHg)     ​ ​

Xcoating-Logo-TM_CMYK.pngXcoating™ Surface Coating, Terumo Corporation's biocompatible amphiphilic polymer surface coating, is a standard feature on the CAPIOX® RX Oxygenators.

Item specifications

Choose the blood outlet port configuration that best suits your circuit.

West outlet port
Oxy inlet on right when outlet is
facing away from user

​East outlet port
Oxy inlet on left when outlet is
facing away from user

both.png 

CAPIOX® RX15 Oxygenator


Description​Catalog #Units/Case
CapioxRX15 Oxygenator.jpg​ ​ ​ ​ ​ ​Hollow fiber oxygenator1
CX*RX15E​4​
​Hollow fiber oxygenator1
CX*RX15W​
4​
Hollow fiber oxygenator with hardshell reservoir​​2
CX*RX15RE30​4​
Hollow fiber oxygenator with hardshell reservoir​2
CX*RX15RW30​4​
Hollow fiber oxygenator with hardshell reservoir​
CX*RX15RE40​4​
​Hollow fiber oxygenator with hardshell reservoir​
​CX*RX15RW404​

1 Contains two adapters 1/4" - 3/8"

2 Contains four adapters 1/4" - 3/8"


CAPIOX® RX25 Oxygenator

Description​Catalog #​Units/Case
​ ​ ​ ​CapioxRX25 Oxygenator.jpg​Hollow fiber oxygenator
​CX*RX25E4​
​Hollow fiber oxygenator​
​CX*RX25W4​
Hollow fiber oxygenator with hardshell reservoir​
CX*RX25RE​4​
Hollow fiber oxygenator with hardshell reservoir​
CX*RX25RW​4​

 

​Holders for CAPIOX® RX Oxygenators

​Description​Catalog #​Units/Case
XX_CXH25F.png
​Holder for Capiox® RX15 and RX25 oxygenator when separated from reservoir
XX*CXH25F​​1
cx15.PNG
Holder for Capiox® RX15 and RX25 oxygenator without hardshell reservoir
XX*CXH15​​1
XX_CXH18R.jpgHolder for Capiox® RX15 and RX25 oxygenator with hardshell reservoir​ (long angled arm)
XX*CXH18R​​1
XX_XH032.jpgHolder for Capiox® RX15 and RX25 oxygenator with hardshell reservoir (short non-angeled arm)
​XX*XH032​1

 Accessories for CAPIOX® RX Oxygenators

​Description
​Catalog #
​Units/Case
​Blue thermistor wire
​CX*BP021
​10
​Red thermistor wire
​CX*BP022
​10

Do you need more info about this product?

Our sales representatives are here for you.

Contact us
Send us a message
 
I have read and accept Terumo Privacy And Cookies Policy and the Terms Of Use*
I wish to receive information and marketing updates from Terumo.
* mandatory fields

Thank you for contacting us!

We typically respond within 2 business days and will come back to you as soon as possible.

Didn't find your product?

Consult our products in our Product Index

Are you a healthcare professional?

This webpage can include promotional content regarding one or several products of Terumo Europe, or some procedures concerning the use or implantation of such products. This webpage is exclusively intended for healthcare professionals and is in no event directed to the general public


For Pharmaceutical Professionals interested in our B2B products portfolio, please visit Terumo Pharmaceutical Solutions.