Skip Ribbon Commands
Skip to main content

Polyethylene Glycol (PEG)–Epirubicin-Loaded Drug-Eluting Embolic (DEE)-TACE Procedures Utilizing a Combined Approach With 100- and 200-µm Microspheres: Initial Experience

Lucatelli et al.

12/19/2018 -  

Purpose

To report clinical effectiveness, toxicity profile, and prognostic factors of combined 100 μm ± 25 and 200 μm ± 50 epirubicin-loaded polyethylene glycol (PEG) microsphere drug-eluting embolic transcatheter arterial chemoembolization protocol in patients with hepatocellular carcinoma.

Materials and Methods

In this prospective, single-center, single-arm study with 18 months of follow-up, 36 consecutive patients (mean age 69.9 y ± 10.8; 26 men, 10 women; 54 naïve lesions) were treated. Embolization was initiated with 100 μm ± 25 microspheres, and if stasis (10 heart beats) was not achieved, 200 μm ± 50 microspheres were administered. Each syringe (2 mL) of PEG microsphere was loaded with 50 mg of epirubicin. Results were evaluated using Modified Response Evaluation Criteria In Solid Tumors with multidetector computed tomography/magnetic resonance imaging at 1, 3–6, 9–12, and 15–18 months. Toxicity profile was assessed by laboratory testing before and after the procedure. Complications were recorded. Postembolization syndrome (PES) was defined as onset of fever/nausea/pain after the procedure. Patient/lesion characteristics and treatment results were correlated with predicted outcome using regression analysis. Child-Pugh score was A in 86.1% of patients (31/36) and B in 13.9% (5/36).

Results

In 10 of 21 lesions, < 2 cm in diameter (47.5%) stasis was achieved with 100 μm ± 25 microspheres only, whereas all other lesions required adjunctive treatment with 200 μm ± 50 microspheres. Reported adverse events were grade 1 acute liver bile duct injury (3/39 cases, 7.7%) and PES (grade 2; 3/39 cases, 7.7%). Complete response (CR) at 1, 3–6, 9–12, and 15–18 months was 61.1%, 65.5%, 63.63%, and 62.5%. Objective response (CR + partial response) at 1, 3–6, 9–12, and 15–18 months was 83.3%, 65.85%, 63.63%, and 62.5%. No single factor (laboratory testing, etiology, patient status, hepatic status, tumor characteristics, administration protocol) predicted outcomes except for albumin level at baseline for CR (P < .05, odds ratio = 1.09).

Conclusions

The combined microsphere sizing strategy was technically feasible and yielded promising results in terms of effectiveness and toxicity.

Source: https://www.jvir.org/article/S1051-0443(18)31643-9/abstract