Cookie policy

This site uses cookies to improve your user experience. By using this website, you agree that we can place cookies on your device. For further information, please read our Privacy And Cookies Policy

I accept the terms and conditions
Skip Ribbon Commands
Skip to main content

AZUR® Peripheral Hydrocoil - Detachable

Peripheral Coil System

Description

Expanding your capabilities

AZUR® Peripheral HydroCoil® embolization system combines a platinum coil and an expandable hydrogel polymer. The hydrogel coating expands in the direction of less resistance to fill space when introduced into the bloodstream.

Characteristics

Expanding Hydrogel technology that delivers:

  • Permanent mechanical occlusion with less reliance on thrombus formation1
  • Mechanical stability
  • Increased delivery control and long-term durability2

Superior volume filling and packing density2

  • Up to 5.8 times more volume filling than conventional 0.018’’ coils3
  • Up to 4 times more volume filling than conventional 0.035’’ coils3

AZUR® detachable system:

  • Can be retracted and repositioned, reducing the risk of migration
  • Detached in less than one second at the push of a button

General specifications

Cathether ID for Hydrocoil 35

0.038-0.047 in

0.97-1.19 mm


Microcatheter ID for Hydrocoil 18
0.021 - 0.027 in

0.53 - 0.69 mm


Item specifications

​Product Description

​Loop Diameter

​Length

​Code

​AZUR® Detachable 18

​2 mm

​2 cm

​45-480202

​AZUR® Detachable 18

​2 mm

​4 cm

​45-480204

​AZUR® Detachable 18

​3 mm

​2 cm

​45-480302

​AZUR® Detachable 18

​3 mm

​5 cm

​45-480305

​AZUR® Detachable 18

​3 mm

​10 cm

​45-480310

​AZUR® Detachable 18

​4 mm

​5 cm

​45-480405

​AZUR® Detachable 18

​4 mm

​10 cm

​45-480410

​AZUR® Detachable 18

​4 mm

​15 cm

​45-480415

​AZUR® Detachable 18

​4 mm

​20 cm

​45-480420

​AZUR® Detachable 18

​6 mm

10 cm

​45-480610

​AZUR® Detachable 18

​6 mm

​15 cm

​45-480615

​AZUR® Detachable 18

​6 mm

20 cm

​45-480620

​AZUR® Detachable 18

​8 mm

​10 cm

​45-480810

​AZUR® Detachable 18

​8 mm

​15 cm

​45-480815

​AZUR® Detachable 18

​8 mm

​20 cm

​45-480820

​AZUR® Detachable 18

​10 mm

​10 cm

​45-481010

​AZUR® Detachable 18

​10 mm

15 cm

​45-481015

​​AZUR® Detachable 18

​10 mm

​20 cm

​45-481020

​AZUR® Detachable 18

​12 mm

15 cm

​45-481215

​AZUR® Detachable 18

​12 mm

20cm

45-481220

​AZUR® Detachable 18

​15 mm

​15 cm

45-481515

​AZUR® Detachable 18

​15 mm

​20 cm

​45-481520

​AZUR® Detachable 18

15 mm

​30 cm

45-481530

​AZUR® Detachable 18

​20 mm

20 cm

45-482020

​AZUR® Detachable 18

​20 mm

​30 cm

45-482030

​AZUR® Detachable 35

​3 mm

​5 cm

45-450305

​AZUR® Detachable 35

​4 mm

​5 cm

​45-450405

​AZUR® Detachable 35

​4 mm

​10 cm

45-450410

​AZUR® Detachable 35

​4 mm

​15 cm

​45-450415

​AZUR® Detachable 35

​5 mm

​5 cm

​45-450505

​AZUR® Detachable 35

​5 mm

​10 cm

​45-450510

​AZUR® Detachable 35

​5 mm

15 cm

​45-450515

​AZUR® Detachable 35

​6 mm

​10 cm

​45-450610

​AZUR® Detachable 35

​6 mm

​15 cm

​45-450615

​AZUR® Detachable 35

​6 mm

​20 cm

​45-450620

​AZUR® Detachable 35

8 mm​

​15 cm

​45-450815

​AZUR® Detachable 35

​8 mm

​20 cm

​45-450820

​AZUR® Detachable 35

​10 mm

​15  cm

​45-451015

​AZUR® Detachable 35

​10 mm

​20 cm

​45-451020

​AZUR® Detachable 35

​12 mm

​15 cm

​45-451215

​AZUR® Detachable 35

​12 mm

​20 cm

45-451220

​AZUR® Detachable 35

​15 mm

​20 cm

45-451520

​AZUR® Detachable 35

​15 mm

​30 cm

45-451530

​AZUR® Detachable 35

​20 mm

​20 cm

​45-452020

​AZUR® Detachable 35

​20 mm

​30 cm

​45-452030

​AZUR® Detachment Controller for Use with Detachable System - Pack of 5 Units

​-

​-

​45-4001


Indications for use: The AZUR system is intended to reduce or block the rate of blood flow in vessels of the peripheral vasculature. It is intended for use in the interventional radiologic management of arteriovenous malformations, arteriovenous fistulae, aneurysms, and other lesions of the peripheral vasculature.

MicroVention is a registered trademark of MicroVention, Inc. HydroCoil is a registered trademark of MicroVention, Inc. Terumo is a registered trademark of Terumo Medical Corporation. AZUR is a registered trademark of Terumo. CX is a registered trademark of Terumo. Scientific and clinical data related to this document are on file at MicroVention, Inc. Refer to Instructions for use, contraindications and warnings for additional information – CE0297

Manufacturer Microvention – 1311 Valencia Ave. Tustin, CA 92780, USA - Distributed by: Terumo Europe N.V.


References

1 Fohlen A. Pelage JP. 2017 Peripheral Embolization Using Hydrogel-Coated Coils vs Fibered Coils: Short Term Results In Animal Model. CVIR 2017.
2 Pelage JP. Angiographic and Pathologic Comparison of HydroCoils vs. Fibered Coils Mechanisms of Occlusion and Mid-Term Recanalization in an Animal Model. GEST 2012.

3Data on file at MicroVention TR09-062, TR09-063

Do you need more info?

Our sales representatives are here for you

Contact us

Didn't find your product?

Consult our products in our Product Index

Are you a healthcare professional?

This webpage can include promotional content regarding one or several products of Terumo Europe, or some procedures concerning the use or implantation of such products. This webpage is exclusively intended for healthcare professionals and is in no event directed to the general public