Cookie Policy

This site uses cookies to store information on your computer.

I accept the terms and conditions
Skip Ribbon Commands
Skip to main content

Progreat® - Microcatheter

Accurate distal access and high flow

Terumo presents the Progreat microcatheter system, a technological breakthrough designed for controlled, precise, and selective therapeutic embolization and angiography in peripheral vessels.

Characteristics

Quick

Tungsten spiral coil
The tungsten coil protects inner lumen integrity and provides excellent kink resistance, allowing smooth delivery of all types of embolic materials. It also allows large inner lumen to achieve an optimal flow rate with high pressure (max. 900 psi/ 6.205 kPa)1

Varied outer layer
The varied materials of the outer layer provide stiffness for transition towards the distal tip of the microcatheter, ensuring reliable trackability into narrow and tortuous target vessels1

Fast flushing (coaxial type)
Prime at least 1 mL of heparinized saline solution through the coaxial wire port. Allow more than 10 drops to exit from the microcatheter tip. This activates the coaxial wire's hydrophilic coating and lubricates the inner lumen of the Progreat

Slick

PTFE inner layer
The smooth PTFE surface provides virtually frictionless passage for exceptional precision in guidewire control and embolic agent delivery

M Coat™
Terumo's famous hydrophilic coating facilitates navigation through vascular anatomy, helping to make Progreat a breakthrough in conventional angiographic practice

Three-layer structure
This original structure not only provides Progreat with its world-renowned resistance to kinking, but also enhances its radiopacity and distal flexibility for more precise catheter placement1

Accurate

Varied coil pitch
The varied pitch of the tungsten coil provides microcatheter tip flexibility, thus notably increasing its distal selectivity in tortuous and narrow vessels towards distal lesions1

Optimal visibility
For rapid and precise positioning, Progreat contains three radiopaque components. The structure of the catheter itself is a radiopaque tungsten coil. A specific 0.7 mm platinum/iridium marker indicates the distal end. In the coaxial version, Progreat is delivered with a Radifocus Guidewire GT that includes a 3 cm gold coil at tip

Wire stopper
This device allows variable protruding length of guidewire and provides perfect control of stability and accessibility to the targeted lesion

General Specifications

Catheter inner layerPTFE
Catheter medium layerRadiopaque tungsten coil
Catheter outer layerPolyester elastomer and pigment
Hydrophilic coatingM Coat polymer
Distal radiopaque marker (for some items)One or two radiopaque markers of 0.7mm each
​Catheters outer diameters​2.0 Fr (0.67 mm) / 2.4 Fr (0.80 mm) / 2.7 Fr (0.90 mm) / 2.8 Fr (0.93 mm)
​Catheters inner diameters​0.019'' (0.49 mm) / 0.022" (0.57 mm) / 0.025" (0.65 mm) / 0.027" (0.70 mm)
​Catheters lengths​110 cm / 130 cm / 150 cm (150 cm for 2.4 Fr only)
​Catheters maximum pressure​750 psi (5 171 kPa) / 900 psi (6 205 kPa)
​Guidewire core material (for coaxial versions)​Nitinol
Guidewire outer layer material (for coaxial versions)Polyurethane layer containing tungsten
Guidewire hydrophilic coating (for coaxial versions)M Coat polymer
Guidewire distal marker (for coaxial versions)3 cm gold coil
​Guidewire diameters (for coaxial versions)​0.021" (0.53 mm) (available only for coaxial Progreat)
Guidewire lengths (for coaxial versions)120 cm / 140 cm
Guidewire protruding length from catheter (for coaxial versions)10 cm maximum
Catheter distal curveStraight (shapeable) / 90° (90° for 2.4 Fr only)

Item Specifications

Item referenceDescriptionOuter diameterLengthInner diameterDistal curve0.021" (0.53 mm) Radifocus Guidewire GTGuidewire compatibility0.7 mm radiopaque platinum/ iridium markerMaximum pressureDead volume (hub + catheter)
MC-PC2013Progreat Alpha 2.0 Fr Radiopaque marker2.0 Fr / 0.67 mm130 cm0.019'' / 0.49 mmStraight (shapeable)No0.016'' / 0.41 mm1750 psi / 5171 kPa0.43 ml
MC-PC2015Progreat Alpha 2.0 Fr Radiopaque marker2.0 Fr / 0.67 mm150 cm0.019'' / 0.49 mmStraight (shapeable)No0.016'' / 0.41 mm1750 psi / 5171 kPa0.43 ml
MC-PC2413Progreat 2.4 Fr2.4 Fr / 0.80 mm130 cm0.022'' / 0.57 mmStraight (shapeable)No0.018'' / 0.46 mm0750 psi / 5171 kPa0.53 ml
MC-PB2413Progreat 2.4 Fr Radiopaque marker2.4 Fr / 0.80 mm130 cm0.022'' / 0.57 mmStraight (shapeable)No0.018'' / 0.46 mm1750 psi / 5171 kPa0.53 ml
MC-PC2415Progreat 2.4 Fr2.4 Fr / 0.80 mm150 cm0.022'' / 0.57 mmStraight (shapeable)No0.018'' / 0.46 mm0750 psi / 5171 kPa0.58 ml
MC-PX2413 Progreat 2.4 Fr Pre-shape Angle 90°2.4 Fr / 0.80 mm130 cm0.022"/ 0.57 mm90° AngleNo0.018'' / 0.46 mm0750 psi / 5171 kPa0.53 ml
MC-PV2415YProgreat 2.4 Fr Double markers2.4 Fr / 0.80 mm150 cm0.022'' / 0.57 mmStraight (shapeable)No0.018'' / 0.46 mm2 (3 cm proximal to distal)750 psi / 5171 kPa0.58 ml
MC-PP27111Progreat 2.7 Fr Coaxial2.7 Fr / 0.90 mm110 cm0.025'' / 0.65 mmStraight (shapeable)Yes0.021'' / 0.53 mm0750 psi / 5171 kPa0.57 ml
MC-PP27131Progreat 2.7 Fr Coaxial2.7 Fr / 0.90 mm130 cm0.025'' / 0.65 mmStraight (shapeable)Yes0.021'' / 0.53 mm0750 psi / 5 171 kPa0.64 ml
MC-PC2813Progreat Ω 2.8 Fr2.8 Fr / 0.93 mm130 cm0.027'' / 0.70 mmStraight (shapeable)No0.021'' / 0.53 mm0900 psi / 6205 kPa0.68 ml
MC-PE28131ZBProgreat Ω 2.8 Fr Coaxial Radiopaque marker2.8 Fr / 0.93 mm130 cm0.027'' / 0.70 mmStraight (shapeable)Yes0.021'' / 0.53 mm1900 psi / 6205 kPa0.68 ml
MC-PV2815Y

Progreat Ω 2.8 Fr

Double markers

2.8 Fr / 0.93 mm150 cm0.027'' / 0.70 mmStraight (shapeable)No0.021'' / 0.53 mm2 (3 cm proximal to distal)900 psi / 6205 kPa0.73 ml

 Please quote above item reference codes when placing an order.

 

 

 

 

 

 

 

 

References

1 Bench testing done by Terumo Corporation. Data on file (TC-Pro107). Bench test data may not necessarily be indicative of clinical performance.

Did you not find the product you were looking for ?